亚洲精品乱码久久久久久中文字幕_国产超碰人人模人人爽人人添_亚洲AV无码国产精品色午夜_中文字幕无码无码专区

您現在的位置:首頁 > 技術文章 > 細菌培養箱使用時的注意事項

細菌培養箱使用時的注意事項

  • 更新日期:2023-08-17      瀏覽次數:396
    • 1、插(cha)上電源插(cha)按下霉菌培養箱的電源開關(guan),顯(xian)示屏所顯(xian)示的是培養箱室內(nei)的實際溫(wen)度和濕度。
      2、鏈(lian)接加(jia)(jia)濕(shi)(shi)(shi)器的(de)(de)電源(yuan),插(cha)頭插(cha)在(zai)儀器背面的(de)(de)電源(yuan)插(cha)座上,將儀器的(de)(de)加(jia)(jia)濕(shi)(shi)(shi)管與加(jia)(jia)濕(shi)(shi)(shi)器相連(lian),檢查是否緊密連(lian)接。給加(jia)(jia)濕(shi)(shi)(shi)器水箱里加(jia)(jia)水(參照(zhao)說明書正確操作)。加(jia)(jia)濕(shi)(shi)(shi)器若有故障,請按加(jia)(jia)濕(shi)(shi)(shi)器使用說明書上的(de)(de)保修點(dian),就近修理。
      3、按(an)(an)下溫(wen)(wen)(wen)度(du)(du)按(an)(an)鈕,此時(shi)數字顯示(shi)(shi)(shi)即為設定(ding)值(zhi),旋轉溫(wen)(wen)(wen)度(du)(du)調至(zhi)所需溫(wen)(wen)(wen)度(du)(du)值(zhi),數字顯示(shi)(shi)(shi)即為培養(yang)室(shi)內(nei)的(de)(de)實(shi)際溫(wen)(wen)(wen)度(du)(du)。例(li)如培養(yang)箱(xiang)內(nei)的(de)(de)實(shi)際溫(wen)(wen)(wen)度(du)(du)比設定(ding)溫(wen)(wen)(wen)度(du)(du)小,加(jia)熱(re)指(zhi)示(shi)(shi)(shi)燈亮,加(jia)熱(re)器開(kai)始(shi)加(jia)熱(re);如霉(mei)菌培養(yang)箱(xiang)內(nei)的(de)(de)實(shi)際溫(wen)(wen)(wen)度(du)(du)比設定(ding)溫(wen)(wen)(wen)度(du)(du)大,制冷(leng)(leng)指(zhi)示(shi)(shi)(shi)燈亮,制冷(leng)(leng)系統開(kai)始(shi)制冷(leng)(leng);如加(jia)熱(re)指(zhi)示(shi)(shi)(shi)燈與(yu)制冷(leng)(leng)指(zhi)示(shi)(shi)(shi)燈均(jun)暗,則(ze)培養(yang)箱(xiang)處于恒(heng)溫(wen)(wen)(wen)狀態。、當溫(wen)(wen)(wen)度(du)(du)設定(ding)好之(zhi)后(hou),不(bu)要將(jiang)控(kong)溫(wen)(wen)(wen)旋鈕來回多次(ci)旋轉,壓(ya)縮機啟(qi)動(dong)頻繁(fan),則(ze)會造成(cheng)壓(ya)縮機出現(xian)過(guo)載現(xian)象(xiang),直接影響壓(ya)縮機的(de)(de)使用壽命。 在使用溫(wen)(wen)(wen)度(du)(du)較低時(shi),應定(ding)期清理掉箱(xiang)內(nei)底部(bu)積(ji)水(shui)(shui)盤內(nei)的(de)(de)積(ji)水(shui)(shui)。濕度(du)(du)長期不(bu)用時(shi),請(qing)將(jiang)盒(he)內(nei)水(shui)(shui)倒盡。
      4、濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)調節:選擇濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)設(she)定(ding)按鈕(niu),當(dang)前數(shu)字顯示即為設(she)定(ding)值(zhi),旋轉濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)調至所需濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)值(zhi),松(song)開(kai)(kai)即可,此時(shi)數(shu)字顯示即為霉菌培養箱內(nei)(nei)的(de)實際濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)。當(dang)培養室內(nei)(nei)的(de)實際濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)比設(she)定(ding)的(de)濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)小(xiao)時(shi),此時(shi)加(jia)(jia)濕(shi)(shi)(shi)(shi)(shi)(shi)對培養室內(nei)(nei)加(jia)(jia)濕(shi)(shi)(shi)(shi)(shi)(shi),加(jia)(jia)濕(shi)(shi)(shi)(shi)(shi)(shi)指(zhi)示燈亮;當(dang)培養室內(nei)(nei)的(de)實際濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)比設(she)定(ding)的(de)濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)值(zhi)大時(shi),此時(shi)加(jia)(jia)濕(shi)(shi)(shi)(shi)(shi)(shi)器(qi)停止工作,加(jia)(jia)濕(shi)(shi)(shi)(shi)(shi)(shi)指(zhi)示燈滅。由于濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)傳感器(qi)長時(shi)間處于高濕(shi)(shi)(shi)(shi)(shi)(shi)狀態,便(bian)會形成結露即濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)顯示值(zhi)會居高不下。如(ru)果需要準確的(de)濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)顯示值(zhi),那么應該(gai)關機后,將箱門打開(kai)(kai),讓濕(shi)(shi)(shi)(shi)(shi)(shi)度(du)(du)傳感器(qi)處于室溫中(zhong),自然(ran)干燥后,可再繼續使用。
      5、機(ji)器運轉出現故障(控(kong)溫失靈,不加(jia)熱或不制(zhi)(zhi)冷)馬上切(qie)斷電(dian)源(yuan)(yuan),檢(jian)查(cha)機(ji)背部裝的保(bao)險盒,2A:為制(zhi)(zhi)冷加(jia)熱負(fu)載保(bao)險絲盒,8A:為控(kong)制(zhi)(zhi)電(dian)源(yuan)(yuan)保(bao)險絲盒。看(kan)看(kan)保(bao)險絲是否完好,檢(jian)查(cha)相(xiang)應的部位(wei)。
      6、如箱(xiang)內不需殺(sha)菌(jun)時,應將(jiang)面板上的殺(sha)菌(jun)開關(guan)置于“關(guan)"的位(wei)置。
      7、當儀器在(zai)停(ting)止使用(yong)時,應拔掉電源插頭(tou)。
      8、搬(ban)運時(shi)小心,搬(ban)運時(shi)與水平面的夾角(jiao)不得小于45°
      9、為(wei)了保持設備的美觀(guan),不準(zhun)用酸或(huo)堿及其它腐蝕性物品來擦表面,箱內(nei)可以用干布定期擦干。