您現在的位置:首頁 > 技術文章 > 溶漿機的應用原理

溶漿機的應用原理

  • 更新日期:2022-12-30      瀏覽次數:1067
    • 溶(rong)漿機高使(shi)(shi)用溫度(du)(du)不(bu)能超過40℃,當溫度(du)(du)到(dao)達(da)設定溫度(du)(du)時(shi),加熱器(qi)(qi)停(ting)(ting)止工(gong)作。緩(huan)慢調節調速(su)旋鈕,升至(zhi)所需轉速(su)。每次(ci)(ci)停(ting)(ting)機前,各開(kai)關(guan)置于(yu)非工(gong)作狀態,切斷電(dian)源(yuan)。長期(qi)停(ting)(ting)用儀(yi)器(qi)(qi),應(ying)將儀(yi)器(qi)(qi)內(nei)擦洗干凈。正確的(de)使(shi)(shi)用和注意儀(yi)器(qi)(qi)的(de)保養,使(shi)(shi)其處(chu)于(yu)良好的(de)工(gong)作狀態,可(ke)延長儀(yi)器(qi)(qi)的(de)使(shi)(shi)用壽(shou)命。儀(yi)器(qi)(qi)在連(lian)續工(gong)作期(qi)間,每三個月應(ying)做一次(ci)(ci)定期(qi)檢(jian)查(cha),檢(jian)查(cha)是否有水(shui)滴污物等(deng)落入電(dian)機和控(kong)(kong)制元(yuan)件上(shang),檢(jian)查(cha)水(shui)箱內(nei)的(de)水(shui)質及清潔(jie)程(cheng)度(du)(du),檢(jian)查(cha)保險絲、控(kong)(kong)制元(yuan)件及緊固螺釘。傳動部分(fen)的(de)軸承在出廠前已填充了適(shi)量的(de)潤滑脂(一號鈣-鈉基),儀(yi)器(qi)(qi)在連(lian)續工(gong)作期(qi)間,每六個月應(ying)加注一次(ci)(ci)潤滑脂,填充量約占(zhan)軸承空間的(de)1/3。

      血(xue)液溶漿機經長期使(shi)用,自然磨損屬正(zheng)(zheng)(zheng)常(chang)現(xian)(xian)(xian)象,儀器(qi)在使(shi)用一(yi)年之后(hou),若發(fa)現(xian)(xian)(xian)電機有不正(zheng)(zheng)(zheng)常(chang)的(de)噪聲,傳動部分軸(zhou)承(cheng)磨損,皮(pi)帶松動或(huo)出(chu)(chu)現(xian)(xian)(xian)裂紋(wen),加熱(re)恒溫出(chu)(chu)現(xian)(xian)(xian)異常(chang),電控元(yuan)件失效等(deng)故障,本公(gong)司將繼續提供服(fu)務予以協助處理(li)。傳感器(qi)誤(wu)差的(de)修正(zheng)(zheng)(zheng),在確(que)認儀表(biao)(biao)顯示(shi)的(de)值(zhi)不是正(zheng)(zheng)(zheng)確(que)的(de)測量(liang)值(zhi)時(shi)可(ke)對(dui)顯示(shi)值(zhi)進行修正(zheng)(zheng)(zheng)。按SET鍵3秒進入儀表(biao)(biao)內層菜單(dan),選定參數(shu)SC后(hou)配(pei)合△或(huo)▽鍵可(ke)修改此參數(shu)。傳感器(qi)誤(wu)差的(de)修正(zheng)(zheng)(zheng)的(de)范圍為+50到-50,修正(zheng)(zheng)(zheng)完成(cheng)后(hou)再按SET鍵3秒退出(chu)(chu)。儀表(biao)(biao)出(chu)(chu)廠時(shi)修正(zheng)(zheng)(zheng)值(zhi)為0,使(shi)用時(shi)要防止把顯示(shi)正(zheng)(zheng)(zheng)確(que)的(de)儀表(biao)(biao)修正(zheng)(zheng)(zheng)至不正(zheng)(zheng)(zheng)確(que)。

      啟動(dong)(dong)自整定(ding)(ding)(ding),本產品能適應絕(jue)大多數(shu)(shu)控(kong)制(zhi)系統,只有控(kong)制(zhi)效果(guo)不(bu)理想時(shi)方可啟動(dong)(dong)自整定(ding)(ding)(ding),按(an)(an)SET鍵(jian)(jian)3秒進入(ru)儀(yi)(yi)表內層菜單,選定(ding)(ding)(ding)參數(shu)(shu)At后配合△或▽鍵(jian)(jian)開(kai)啟自整定(ding)(ding)(ding),此時(shi)At指示燈開(kai)始閃爍儀(yi)(yi)表進入(ru)自動(dong)(dong)整定(ding)(ding)(ding)參數(shu)(shu)工(gong)作狀(zhuang)態(tai)(tai),儀(yi)(yi)表控(kong)制(zhi)加(jia)(jia)熱系統在設(she)定(ding)(ding)(ding)點(dian)付近波(bo)動(dong)(dong)二(er)次,當At燈滅時(shi)自整定(ding)(ding)(ding)結(jie)束(shu),新的(de)PID參數(shu)(shu)被(bei)鎖存在芯片中(zhong)。使用儀(yi)(yi)器(qi)前,先將(jiang)調(diao)速(su)旋(xuan)鈕置于小位置。裝(zhuang)培養試(shi)瓶(ping)(ping),注意(yi)(yi)均勻分布,注意(yi)(yi)裝(zhuang)液量不(bu)能偏少(shao)防(fang)止(zhi)產生試(shi)瓶(ping)(ping)漂(piao)浮,注意(yi)(yi)密封好試(shi)瓶(ping)(ping)口,防(fang)止(zhi)凝結(jie)的(de)水珠滴入(ru)試(shi)瓶(ping)(ping)。接通外電(dian)(dian)源(yuan),將(jiang)電(dian)(dian)源(yuan)開(kai)關(guan)置于“開(kai)"的(de)位置,指示燈亮。選擇恒溫(wen)溫(wen)度,設(she)定(ding)(ding)(ding)溫(wen)度: 按(an)(an)SET鍵(jian)(jian)可設(she)定(ding)(ding)(ding)溫(wen)度,按(an)(an)SET鍵(jian)(jian)下(xia)(xia)排數(shu)(shu)碼管數(shu)(shu)據(ju)閃動(dong)(dong)(上排正常測(ce)溫(wen)),表示儀(yi)(yi)表進入(ru)溫(wen)度設(she)定(ding)(ding)(ding)狀(zhuang)態(tai)(tai),按(an)(an)△鍵(jian)(jian)設(she)定(ding)(ding)(ding)值增(zeng)加(jia)(jia),按(an)(an)▽鍵(jian)(jian)設(she)定(ding)(ding)(ding)值減小,持續(xu)按(an)(an)增(zeng)加(jia)(jia)鍵(jian)(jian)或減少(shao)鍵(jian)(jian)設(she)定(ding)(ding)(ding)值會快(kuai)速(su)變化,再按(an)(an)一下(xia)(xia)SET鍵(jian)(jian)儀(yi)(yi)表回到正常工(gong)作狀(zhuang)態(tai)(tai)溫(wen)度設(she)定(ding)(ding)(ding)完畢。